The most distinctive detail in the set. Tiling is bonded directly to the sprayed INSULTERM 600 face — no board, no furring, no board joints or screw heads behind the tiling. That saves 28 mm on every wet wall, which is net internal area recovered on every bathroom in a scheme. At 133 mm it is the thinnest build-up Solid System publishes.
Wet-area partition
The layer schedule for this detail is being transcribed from the construction details catalogue and signed off by the technical department. The total thickness above is confirmed. Contact the technical department for the current build-up on a live scheme.
Layer schedule
The layer schedule for D.05 is being transcribed from the construction details catalogue and signed off by the technical department. The confirmed total thickness is 133 mm.
Performance
| Property | Value | Basis |
|---|---|---|
| U-value, bridging corrected | 0.60 W/m²K | EN ISO 6946, one-dimensional steady state, with a +20% bridging correction applied as an engineering estimate. |
| Self-weight | 80 kg/m² | Mass estimate from the layers and dimensions in the source document. |
| Traditional equivalent | 129 kg/m² | Derived from the published self-weight and reduction percentage. |
| Weight reduction | 38 % | Self-weight against the traditional equivalent build-up. |
| Fire resistance (EI) | Test programme in progress — contact technical department | Awaiting laboratory test report |
| Airborne sound reduction (R_A) | Test programme in progress — contact technical department | Awaiting laboratory test report |
| Watertightness | Test programme in progress — contact technical departmentBond strength testing to EN 1348 is in progress | Awaiting laboratory test report |
U-values are one-dimensional steady-state calculations to EN ISO 6946. Bridging correction is applied as an engineering estimate: +20% for walls, +15% for horizontal elements. 2D numerical analysis to EN ISO 10211 is in progress; values will be updated on completion.
Not yet stated
- EIFire resistance · in test
- R_AAirborne sound reduction · in test
- watertightnessWatertightness · in test
Test programme in progress — contact technical department