Thermal performance

Calculated U-values for all nine details, with the method stated and the correction described. Nothing here is measured; everything here is checkable.

All details · calculated thermal performance
Detail Thickness U (1D) U (corrected)
D.01 Terrace parapet 217 mm
D.02 Façade envelope wall 228 mm 0.359 W/m²K 0.43 W/m²K
D.03 Internal load-bearing wall 196 mm 0.45 W/m²K
D.04 Internal partition 146 mm 0.55 W/m²K
D.05 Wet-area partition 133 mm 0.60 W/m²K
D.06 Foundation slab 510 mm
D.07 Intermediate floor 528 mm 0.26 W/m²K
D.08 Non-trafficable roof 603 mm 0.21 W/m²K
D.09 Trafficable roof / terrace 570 mm 0.21 W/m²K

U-values are one-dimensional steady-state calculations to EN ISO 6946. Bridging correction is applied as an engineering estimate: +20% for walls, +15% for horizontal elements. 2D numerical analysis to EN ISO 10211 is in progress; values will be updated on completion.

Method

Values are one-dimensional steady-state calculations to EN ISO 6946. Bridging corrections are applied as engineering estimates: +20% for walls, +15% for horizontal elements. Two-dimensional numerical analysis to EN ISO 10211 is in progress and values will be updated on completion.