Esta sección aún no está disponible en español. Se muestra el texto original en inglés: la traducción técnica requiere la validación del departamento técnico antes de publicarse.

Material register

Every material used across the nine details, with its class, thermal conductivity and density where the source document states them.

11 of 22 entries published
Drawing label Material Class λ Density Used in
INSULTERM 600 INSULTERM 600 The only proprietary material in the verified set. Encapsulates the steel frame and building services, forming a low-density monolithic element. Spray-applied thermal-acoustic conglomerate 0.138 W/m·K 600 kg/m³ D.01 · D.02 · D.03 · D.04 · D.05
Placner Placner ribbed steel sheathing 0.3 mm base sheet, Z200 zinc coating as standard, Z275 available and specified for coastal and marine exposure. Panel 600 × 2,500 mm (1.5 m²). Cold-rolled galvanised steel sheet, V-form ribs D.01 · D.02 · D.03 · D.04 · D.05
C140 Cold-formed galvanised C-stud, 140 mm Load-bearing walls and façades. Cold-formed galvanised steel D.02 · D.03
C90 Cold-formed galvanised C-stud, 90 mm Partitions. Cold-formed galvanised steel D.04 · D.05
Joist 250–400 Cold-formed steel joist, 250 / 300 / 350 / 400 mm Depth range only. Span capacity is not stated — selection tables in preparation. Cold-formed galvanised steel D.07 · D.08 · D.09
Rock wool Mineral wool Cold side of the stud cavity, where the temperature gradient is steepest. Mineral fibre insulation D.02
Pladur Pladur plasterboard Internal lining. Gypsum board D.02 · D.03 · D.04
Aquapanel Aquapanel cement board Must not be substituted with standard plasterboard on the parapet. Cement-bonded board D.01
Monocapa Monocapa render External finish. Single-coat mineral render D.02
XPS Extruded polystyrene 50 mm standard; reduced to 30 mm in the D.08-C Canary Islands variant. Rigid foam insulation D.08
Omega Omega channel Two decoupled channels form the mass–spring–mass arrangement. Cold-formed galvanised steel D.03

The complete 22-row register lives in the source document (SOLID SYSTEM — Construction Details Catalog). The rows below are the materials named in the build brief, with λ and density stated only where the brief states them. The remaining rows, and the λ and density values left null here, arrive with the signed structured detail data — open item 4.