Esta sección aún no está disponible en español. Se muestra el texto original en inglés: la traducción técnica requiere la validación del departamento técnico antes de publicarse.

Climate optimisation — Canary Islands

Two specifications, maintained deliberately. The full build-up for mainland and export markets. A climate-optimised variant for the Canaries and comparable subtropical markets.

This is an engineering service, not a discount. The variants remove material that the climate does not require, and each one is calculated rather than estimated.

Variant Change Revised U Zone α Material reduction
D.02-C External INSULTERM 600 reduced from 50 to 30 mm; cavity rock wool omitted and the 140 mm cavity filled with INSULTERM 600. 0.62 Complies 20 mm less external INSULTERM 600; rock wool eliminated.
D.08-C XPS reduced from 50 to 30 mm. 0.26 Complies 20 mm less XPS.

The fire and acoustic consequences of the reduced build-ups require separate verification.

Two specifications, maintained deliberately. The full build-up for mainland and export markets. A climate-optimised variant for the Canaries and comparable subtropical markets.